Holiday Detection of Internal Tubular Coatings of Less Than 330 µm (13 mils) Dry-Film Thickness
This nondestructive test method describes a procedure to detect discontinuities (“holidays”) in thin-film polymeric coatings of less than 330 µm (13 mils) dry film thickness (DFT) applied to the internal surfaces of metallic tubular goods used in the oil and gas industry. The apparatus and the recommended procedure for performing the test are described, as are methods of reporting the test data.
A separate test method, NACE TM0186, addresses holiday detection of internal tubular good coatings of 330 to 760 µm (13 to 30 mils) dry-film thickness.
TM0384 was created to identify coating film discontinuities on the internal surfaces of tubular goods to maximize the mitigation of corrosion in these areas. The updates in this revision include updates to the calibration process and grounding guidance.