The moisture vapor emission rate (MVER) of concrete floors affects the selection of flooring materials for both new construction and remodel projects. The MVER is determined by exposing a 20" x 20" test area to calcium chloride for 60 to 72 hours. Because of the length of time and size of the test areas required for the calcium chloride test, it would be advantageous if the instantaneous results provided by moisture meters could be used for decision-making. This paper presents the data obtained from field studies that compared calcium chloride test results with 3 different types of moisture meters.
© 2012 Association for Materials Protection and Performance (AMPP). All rights reserved. This work is protected by both domestic and international copyright laws. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).