1-20 of 33
Keywords: permeation
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

... isolation capabilities( 13 ). With pressure, the “leak to seal” design of GRE faced, metal cored gaskets can absorb water reducing the isolating properties (see table 2 below). While the design of a metal cored gasket eliminates potential issues with permeation from ID to OD, it can in turn lower...
Proceedings Papers

...electrochemical impedance disbonding epoxy cathodic disbonding permeation pore of resistance INTRODUCTION A research as need arises from the operation in oilfield, where fluids are produced with temperatures above 120°C, the soil around the buried pipeline has a lower temperature...
Proceedings Papers

... will be presented on the different types of applications. Finally, six cases will be presented. One of the cases will be desulfurization of flue gas at high temperatures. Fluoroplastics coating processes corrosion protection non-stick permeation Polytetrafluoroethylene (PTFE) is the most well known fluorplastic...
Proceedings Papers

... to monitor the permeation of Fuel C across the laminate into the aqueous environment. Findings to date show that after 37 months of exposure, a 1 mm thick isophathic laminate indicates no permeation of Reference Fuel C across the laminate into the adjacent environment. Permeation thermoset isophthalic...
Proceedings Papers

... control of the pipeline corrosion. pipeline coating cathodic protection corrosion crevice permeation INTRODUCTION Corrosion of metals is an electrochemical process. To prevent or mitigate corrosion of underground pipelines, a combination of CP and a barrier coating are generally used. CP works...
Proceedings Papers

...flue gas desulfurization (FGD) plants water solutions water vapor permeation polymer lining systems blistering resistance INTRODUCTION In scrubber heads, and also outlet ducts, water vapor saturated, corrosive gases are found. Due to these service conditions, it is necessary to use corrosion...
Proceedings Papers

... behind permeation and can not be evaluated by immersed coupon testing. The ASTM C-868 cell tested is limited to atmospheric test conditions which invariably limits the temperatures at which tests can be run. This manufacturer has adapted the C868 procedure to allow for a steam cell test in order...
Proceedings Papers

... aqueous corrosion scenarios of industrial interest which induce hydrogen permeation through steel at 20-25 °C, and which are therefore amenable to hydrogen flux monitoring of steel corrosion at ambient temperatures. Initially, it was established that hydrogen flux exiting steel as a result of corrosion...
Proceedings Papers

...The next experiment was set up identically with the exception that two Plate B’s were used. One Plate B was metalized using the same installer and coating system as used in the rich amine flash drum. Results from permeation monitoring during the test are shown in Figure 3 . Figure 4 shows...
Proceedings Papers

...Abstract These first explicit measurements of permeation on thin membranes have so far raised more questions than they have answered. In particular, thin membranes demand more accurate measuring techniques, and a simple transposition of the methods employed for thick membranes is not always...
Proceedings Papers

...steel hydrogen charging internal hydrogen external hydrogen hydrogen stress cracking H2S sulfide stress cracking permeation INTRODUCTION The new mechanisms for hydrogen charging and hydrogen stress cracking recalled in Part I of the present study 1 have been proposed...
Proceedings Papers

...DISCUSSION The objective of the project was to develop a fast response hydrogen permeation probe to allow process engineers to control the plant in order to “real time monitor”, and ultimately, avoid H2S damage to the carbon steel refinery equipment. The probe specification included EIS...
Proceedings Papers

... Alloy 600 tubing (0.18” ID). The outer diameter of this tubing was turned down to 0.24” in an effort to reduce the permeation distance (i.e., permeation distance of 0.03”). The material composition of the Alloy 600 tubing is provided in Table 1 . The reduced diameter Alloy 600 tubing...
Proceedings Papers

... then lead to a stress dependent cracking process. These assumptions are so far the only ones compatible with all the experimental data. However, they raise many basic questions, such as the role of pH, CO2 and HAc, the need for a new type of permeation test, and the relationship between...