Proceedings Papers

... conclusions. These are summarized in the next page. Commercially-available AISI 41xx low-alloy steel bar stock at 110ksi (758MPa) SMYS is susceptible to SSC cracking at or below 175°F (79°C). The minimum acceptable service temperature for such commercial high strength 41xx grades are thus well above...
Proceedings Papers

... assessment is advisable. In the absence of creep data for the material heats in question, the assumption must be made that the creep properties are not better than the minimum provided by the appropriate database. This assumption can be overly conservative. Creep rupture strength for low-alloy steels...
Proceedings Papers

...]) low-alloy steel superheater tubing from an “A-Frame” package boiler was analyzed after a 10-month service period. While in service the tube was located in the superheater bank just downstream from the inlet supply header. Boiler feedwater was a combination of steam condensate and demineralized water...