1-20 of 59
Keywords: intergranular corrosion
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

... of other alloys traditionally used by the oil and gas and chemical processing industries. Alloy 642 pitting corrosion stress corrosion cracking intergranular corrosion phase stability weldability impact energy clad pipe INTRODUCTION UNS (1) N06625 (alloy 625) is one of the most commonly...
Proceedings Papers

...It is notable that these tests are intended to be comparative tests, whereby the corrosion rate of annealed ‘control’ material should be compared to that of the sensitized material. There are several test methods available for intergranular corrosion testing, and the test method should be chosen...
Proceedings Papers

... electrochemical potentiokinetic reactivation (DL-EPR), and potentiodynamic polarization to characterize the intergranular corrosion and pitting corrosion resistance. The goals of this effort are to provide more details on the corrosion resistance of the HAZ for engineering applications. EXPERIMENTAL PROCEDURE...
Proceedings Papers

... ratio and good weldability. Alloys containing more than 3 wt% Mg, when exposed to standard service temperatures for extended periods of time, can become sensitized and susceptible to localized corrosion; particularly intergranular corrosion (IGC). Many studies have investigated this IGC phenomenon...
Proceedings Papers

..., no additional polishing was performed. This might introduce some artifact on the SKPFM images. Aluminum alloys Hydrogen desorption Scanning Kelvin Probe Force Microscopy (SKPFM) Intergranular corrosion Hydrogen embrittlement INTRODUCTION 2024 aluminum alloy (AA 2024) is widely used in aeronautics due...
Proceedings Papers

... and patrol boats as well as in Navy ships have shown that the 5XXX series is prone to elemental migration and phase transformations at only slightly elevated temperatures (i.e., sensitization), leading to localized intergranular corrosion and stress corrosion cracking. In order to maximize structural...
Proceedings Papers

...-Li alloys stress corrosion cracking exfoliation corrosion intergranular corrosion corrosion aggressive environments INTRODUCTION The requirements to present day materials have extended considerably the spectrum of aluminium alloys application. For example, extruded profiles of UNS A96063-T6...
Proceedings Papers

... in reprocessing plants. In almost all nitric media, these materials remain in their passive state. However, in the presence of oxidizing ions, their corrosion potential may be shifted towards their transpassive domain. In this domain they can suffer intergranular corrosion which limits their lifetime. Oxidizing...
Proceedings Papers

... the susceptibility of certain Ni-rich, Cr-bearing alloys to intergranular corrosion. 7 In accordance with the specification, samples were tested for 24 hours. The purpose of the oxidizing G28-A test is to “detect susceptibility to intergranular corrosion as influenced by variations in processing...
Proceedings Papers

...Abstract For characterization of susceptibility to intergranular corrosion different test methods are used. These tests are immersion test, such as Streicher-, Strauss- or Huey- test, as well as electrochemical methods, like the EPR test (electrochemical potentiokinetik reactivation...
Proceedings Papers

... temperature and cooling rate) on microstructure and corrosion properties of UNS 06625 1 used as a cladding material in oil and gas industry, was investigated. In addition, the effect of different annealing treatments was determined. Susceptibility to intergranular corrosion was investigated...
Proceedings Papers

... materials for preventing galvanic corrosion of dissimilar metals. Corrosion non-metallic corrosion general corrosion galvanic corrosion crevice corrosion pitting corrosion selective leaching erosion corrosion stress corrosion cracking intergranular corrosion plastics rubber paints wood...
Proceedings Papers

... part of the steel trays was visually corroded, with black, grey, or rusty brown colored corrosion products. The uncorroded steel surface no longer showed original shiny grey surface, rather a slightly greenish discoloration. Evidence of intergranular corrosion, however, was found in the visually un...