1-15 of 15
Keywords: grout
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

..., distribution of the current from the applied voltage perturbation and grout electrical properties is required. The testing in a general sense allow for detection of the natural corrosion rate. 27 Since corrosion of strand in grout materials typically develops after depassivation by environmental...
Proceedings Papers

... the critical passivation current. Sulfate ions have shown minor indication to increase the anodic current exchange density. Crevice and enhanced temperature did not seem to aggravate corrosion conditions. The pH of deficient grout extracted from corroded bridge tendons was typically ~13, but lower pore water...
Proceedings Papers

...Abstract After recent discovery of corrosion failure of tendons with deficient grout in a Florida bridge, other similar post-tensioned bridges in Florida have been inspected. Other bridges were found to have analogous deficient grout; however, the amount and level of severity of deficient grout...
Proceedings Papers

...Abstract Recently, corrosion problems have occurred with new formulation grouts in post-tensioned tendons that were specified to meet low bleed-water requirements. Severe material deficiencies were observed in external post-tensioned tendons of several bridges in Florida, one of which had tendon...
Proceedings Papers

...Abstract The assessment of recently failed external post-tensioned tendons from a bridge in Florida provided some insight on the material and environmental conditions of the tendon components leading to the failure. Segregated grout material was observed in the vicinity of the corrosion failure...
Proceedings Papers

...Abstract The presence of voids in the grout of post-tensioned tendon ducts provides conditions whereby corrosion development may occur. The causes of the voids have been attributed to development of bleed water during grouting and subsequent re-absorption or evaporation from the grout. Poor...
Proceedings Papers

..., as well EIS and LPR, to detect air space corrosion at the grout voids was also explored. The results showed that high sensitivity noise measurements (in the μV range) are feasible for the strand-anchorage systems. The potential and galvanic current trends for the assemblies suggest the presence...
Proceedings Papers

...MODELING System Modeled The system simulated in this preliminary effort was a simple grouted cylinder with an axially placed 19-strand bundle (see Figure 5 ). The complicating geometry issue of strand distribution in the polyethylene duct as in Figure 5(c) was not taken into consideration...