1-15 of 15
Keywords: chloride stress corrosion cracking
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Proceedings Papers

... are presented specific to the refining industry. Two cases of chloride stress corrosion cracking (Cl-SCC) of 2205 DSS tubing are presented. One of them occurred in an overhead exchanger tube of the crude tower, while the other failure occurred in a top pump-around exchanger tube. The mode of failure...
Proceedings Papers

... H2S and chloride concentrations even under the influence of galvanic coupling. UNS N08904 alloy 904 L hydrogen sulfide carbon dioxide chloride sour brines sulfide stress cracking chloride stress corrosion cracking galvanic coupling INTRODUCTION In earlier times UNS N08904 (alloy 904 L, 1.4539...
Proceedings Papers

... on this phenomenon. duplex stainless steel chloride stress corrosion cracking chloride SCC INTRODUCTION In recent years, use of duplex SS has become more prevalent in the refining industry. With the raw material cost of 2205 duplex SS (S32205) generally on par with 316 SS (S31600), duplex SS has been used more...
Proceedings Papers

... envelops and the integrity concerns due to environmental cracking focusing on case histories primarily related to hydrogen induced cracking, hydrogen blisters and chloride stress corrosion cracking. Moreover, this paper will also focus on the challenges associated in quantifying the magnitude of impact...
Proceedings Papers

... envelopes and the integrity concerns due to environmental cracking focusing on case histories related to hydrogen induced cracking, hydrogen blisters and chloride stress corrosion cracking. Moreover, this paper will also focus on the challenges associated in quantifying the magnitude of impact...
Proceedings Papers

..., chloride and oxygen content for the 22Cr steel and also examined 25Cr duplex and alloy 625. Duplex stainless steels alloy 625 chloride stress corrosion cracking concentration effect INTRODUCTION The Shearwater Development is located some 200 km east of Aberdeen in the Central Graben Area of the Central...
Proceedings Papers

... of advantages. In the present paper, domains of application for the 95ksi grade alloyed 13%Cr steels with respect to sour service conditions have been defined on pH vs. H2S partial pressure plots. Corrosion properties have also been determined for two other aspects; chloride stress corrosion cracking...