Skip Nav Destination
Close Modal
Update search
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
NARROW
Format
Subject
Article Type
Date
Availability
1-13 of 13
Keywords: Aboveground storage tanks
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
...Abstract Lining the floor bottoms and vapor space within an Aboveground Storage Tanks (AST) is a well-proven method to mitigate internal corrosion of the carbon steel substrate. An AST is usually scheduled for out-of-service inspection at least 10 years after its initial in-service date; sometimes...
Proceedings Papers
... professional work together to mitigate all potential corrosion issues and ensure an effective cathodic protection system is designed prior to tank installation. Aboveground Storage Tanks Corrosion Prevention Cathodic Protection Galvanic Corrosion Internal Corrosion Oil & Gas Wastewater Treatment...
Proceedings Papers
... corrosion of the aboveground storage tanks (AST) bottoms’ underside. Prevention of soil-side corrosion of the bottom plates of aboveground crude oil storage tanks is a major challenge in the oil and gas industry. Monitoring an AST bottom corrosion and VCI effectiveness is an important factor in determining...
Proceedings Papers
...Abstract Soil-side corrosion of the bottom plates of aboveground storage tanks is the main cause of tank failure in 90% of the storage tanks in the Middle East. Chemical and topographical analysis of the soil revealed high salt content and sinkholes that lead to porous soil structure...
Proceedings Papers
.... , Baker K. , Singh R. , and Schultz M. . “ Corrosion Protection of Soil Side Bottoms of Aboveground Storage Tanks .” Conference Proceedings of CORROSION 2014 Conference . Paper No. 4337 . ( Houston, TX : NACE , 2014 ). 2 Lyublinski E. , Baker K. , Natale T. , Posner...
Proceedings Papers
... in the case of using VPCI in supplementing ICCP for protection of storage tank bottoms. vapor phase corrosion inhibitor VPCI amine carboxylate corrosion inhibitor impressed current cathodic protection ICCP aboveground storage tanks AST electrical resistance probes ER probes cathodic protection...
Proceedings Papers
... for the installation of monitoring equipment and impressed current cathodic protection are covered. aboveground storage tanks cathodic protection cathodic protection monitoring directional drilling impressed current cathodic protection release detection INTRODUCTION Every now and then, the owner of an above...
Proceedings Papers
... asphalt tanks in a refinery aboveground storage tanks asphalt tanks cathodic protection corrosion monitoring coupons corrosion monitoring probes high temperature cathodic protection monitoring reference electrodes INTRODUCTION To determine the effectiveness of cathodic protection on the exterior...
Proceedings Papers
... ). SYSTEM DESCRIPTION Asphalt product is stored in insulated and heated aboveground storage tanks at temperatures that can exceed 350° F. The high temperatures of the steel tank bottom and surrounding tank cushion can cause rates of corrosion that are 4 to 8 times higher than steel at ambient temperatures...
Proceedings Papers
...Abstract The effectiveness of cathodic protection on the exterior bottoms of aboveground storage tanks is best measured with permanent zinc or copper-copper sulfate reference electrodes placed under the tank bottom. The use of these electrodes is preferable to measurements taken at the periphery...
Proceedings Papers
... flux leakage eddy current tank floor inspection top side corrosion back side corrosion defects aboveground storage tanks nondestructive testing Abstract The first flux leakage type rotary scanning unit for testing 1/4" (6.35 mm) and 3/8" (9.53 mm) flat carbon steel plate and detecting corrosion...
Proceedings Papers
... containment and aboveground storage tanks. With the advent of secondary containment, corrosion soon became a major problem in the life and service of these designs. The designed systems have varied, however, the driving force in the present design is corrosion prevention. The evolution of these designs...
Proceedings Papers
...INTRODUCTION Cathodic protection (CP) is commonly used to mitigate corrosion on the bottoms of aboveground storage tanks. To protect the environment from leaks due to through-floor corrosion, new tanks and refurbishment of old tanks are often designed with double bottoms. Figure 1 and Figure 2...