Skip Nav Destination
Close Modal
Update search
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
Filter
All
- All
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- EISBN
- ISSN
- EISSN
- Issue
- Volume
- References
NARROW
Format
Subject
Article Type
Date
Availability
1-8 of 8
Keywords: Above ground Storage Tanks
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Proceedings Papers
... Corrosion Integrity Management Course Manual . Houston, TX. : NACE International , 2000 . 7 Adelakin T. K. , Math S. and Lindemuth D. , “ External Corrosion Protection of Underside Bottom of Above Ground Storage Tank Using Vaporized Corrosion Inhibitors ”. Corrosion 2017...
Proceedings Papers
..., and long-term performance of the galvanic CP systems in the presence of VCIs. Vapor Corrosion Inhibitors Cathodic Protection Above Ground Storage Tanks CP Anodes INTRODUCTION For effective implementation of a CP system, current generated by anodes is a determining factor, which along with other factors...
Proceedings Papers
... for combined VCI and CP systems. In summary, VCI and CP, used in combination, are found to have a synergistic interaction to mitigate tank–bottom corrosion to acceptable levels. Vapor Corrosion Inhibitors Cathodic Protection Above Ground Storage Tanks CP Criteria INTRODUCTION Aboveground Storage Tanks...
Proceedings Papers
... locations of the tank floor to fog VPCI powder, and four points in ring wall were cored to introduce sleeves for installing of ER probes to monitor the effectiveness of VPCI slurry. Figure 2 . INTRODUCTION The soil side corrosion of above-ground storage tanks (AST’s) is a chronic problem in the oil...
Proceedings Papers
.../CuSO4) are widely used to monitor the structure to electrolyte potential of above-ground storage tank (AST) bottoms. Reference electrodes intended for long-term monitoring are installed under the tank bottom and typically difficult to be practically retrieved or replaced. Dependability of the reference...
Proceedings Papers
...Abstract Innumerable above ground storage tanks in hydrocarbon process plants, which are located in aggressive soil at coastal areas, are at a risk from bottom plate corrosion, due to formation of a galvanic corrosion cell between the tank bottom plate and the soil. This galvanic corrosion cell...
Proceedings Papers
.../ft2 for protection of steel bottom underside. Above ground storage tanks secondary containment HDPE liner cathodic protection impressed current grid system mixed metal oxide coated titanium anode 100 millivolt potential decay INTRODUCTION Saudi Basic Industries Corporations (SABIC) owns...
Proceedings Papers
... installed from approximately 10 ft. (3m) outside the tank perimeter to as near the center of the tank as possible. Installation of the PVC monitoring pipes consisted of: Abstract Initial cathodic protection of twelve above ground storage tank bottoms ranging from 195 ft. (59m) to 280 ft. (85m) in diameter...