Abstract
An experimental study of corrosion of carbon steel in the presence of H2S, CO2 and acetic acid has been carried out. H2S and CO2 partial pressures up to 10 bar each were applied, with temperatures of 25 and 90°C. The test solutions consisted of high-salinity brine (100 g/L NaCl, 150 ppm bicarbonate) and low-salinity condensed water (0.1 g/L NaCl). The duration of the tests was around 14 days. Both weight loss corrosion and localized corrosion data were obtained. The entire surfaces of the exposed coupons were scanned with a 3D profilometer, obtaining detailed data on localized corrosion morphology, pit frequency and pit depths. The results are discussed on the background of previous findings and available literature.
© 2017 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).