Abstract
Sulfur corrosion is usually associated with high H2S systems but sulfur can also be deposited in systems containing small amounts of H2S under conditions where oxygen is allowed to enter the gas stream. Oxygen ingress may be due to air drawn in by elements such as compressors or vapour recovery units on oil tanks or may be carried in by methanol injected for hydrate control. The solubility of oxygen in methanol is significantly higher than in water and sufficient amounts can be present to react with H2S and deposit elemental sulfur. Case histories are presented where this has led to failures in pipelines and downhole equipment.
© 2011 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).