Abstract
Induced Alternating Current on buried pipelines is not new, but the corrosive action of this current on the pipeline is not well known or well documented. Little information is available on how to identify the effects of induced A/C and then develop a program to mitigate the current to acceptable levels. There is also little documentation on how to provide a monitoring system to insure the continued mitigation.
This paper is an attempt to inform the pipeline community of the possibility of AC corrosion on select lines. By conducting various field and laboratory tests, the pipeline company has identified A/C corrosion as the reason for a release in Rockwall County Texas. This paper outlines those tests, their results, the mitigation program developed to remedy the problem, and the monitoring program implemented to insure that the integrity of the system is being maintained.