Abstract
This paper describes an approach used to select corrosion resistant materials for a wet flue gas desulphurization FGD) plant. Material selection and correct application supervision are paramount when designing linings as corrosion control method. The use of various corrosion resistant linings in the major components of the FGD plant were reviewed and some examples of generic lining applications are shown to illustrate the importance to line carbon steel equipments, generally the most cost effective corrosion control measure for this process system.
Government work published by the Association for Materials Protection and Performance (AMPP) with permission of the author(s). Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).
2003