Abstract
An investigation was carried out to determine the effect of nodular cast iron (NCI) microstructure on its cavitation corrosion behavior in natural seawater. The cavitation tests were conducted using cavitation induced facility at a frequency of 20 kHz on detached specimens. Morphological examinations on cavitated specimens indicated that the surface on NCI became very rough with large size caivity pits. Examinations by optical microscopy of cross-sectioned specimens revealed the presence of microcracks in the bottom of cavity pits. Localized material removal on the NCI surface was due to ductile tearing and brittle modes of failure.
© 2001 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).
2001
Association for Materials Protection and Performance (AMPP)