Asbestos cement (AC) piping has been used for potable water, irrigation, drainage and sewer systems for approximately 100 years. The most significant problem affecting the structural integrity of asbestos cement pipes results from the leaching of the cement mortar binder out of the pipe wall. This leaching can occur from the internal surface, depending on the chemical make-up of the water or sewage, or from the external surface, depending on the aggressiveness of the groundwater and soil conditions. This paper describes the findings of test work on AC piping samples from potable water and sewer piping that have been in service for up to 40 to 50 years, and discusses an empirical equation developed by our company to estimate the remaining service life of AC piping systems.

You do not currently have access to this content.