Abstract
The partitioning of a corrosion inhibitor between the oil and water phases has a significant impact on inhibitor selection, treatment philosophy, and inhibitor transport. This work was undertaken to develop information on how inhibitor concentration varies with treatment rate and operational conditions. It was found that partitioning of the selected inhibitor varied by several orders of magnitude dependent on the water cut. With a low water cut, the tested corrosion inhibitor partitioned preferentially into the water phase, and with a high water cut, the inhibitor partitioned into the gas condensate phase. These issues are discussed with respect to laboratory and field measurements.
© 2000 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).
2000
Association for Materials Protection and Performance (AMPP)
You do not currently have access to this content.