Abstract
Chemical dissolution tests and electrochemical tests were carried out on Alloy 600 specimens covered with synthetic deposit simulating the tube deposits in the steam generators at Indian Point 2. The tests showed that the introduction of ETA and a moderate increase in pH gave rise to lower corrosion rates, but enhancement of hydrazine levels caused them to rise. In the case of brass, both types of tests showed that raising the pH caused the corrosion rates to increase, but the introduction of ETA led to mild decrease in these rates.
© 1997 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).