Abstract
This work examines the electrochemical growth of iridium oxide electrodes for use as a pH sensor and further evaluates the usefulness of these probes in a variety of solutions with sulfur-containing anions. Electrodes were grown and calibrated according to reports in the literature and exposed to sulfate-, sulfite-, bisulfite-, and thiosulfate- containing solutions in various concentrations. No effect of changes in sulfate and sulfite ion concentration were observed, however, significant changes in the calibration behavior of the electrodes was observed after the exposure to the solutions with bisulfite and thiosulfate ions.
© 1997 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).