Abstract
A new set of fracture mechanics stress corrosion crack growth rate data is presented for transgranular cracking of reactor pressure steels in high temperature water. The essential observations are as follows. Fast stress corrosion crack growth rates between 10-9 and 10-8 m/s may be observed down to 400 ppb dissolved oxygen at water conductivities of 1.0 μS/cm in refreshed autoclaves. Stress corrosion crack growth could not be observed below minus 270 mV on the hydrogen scale. Low and medium sulfur contents in the steels have no measurable influence on the stress corrosion crack growth rates in 288°C water with a conductivity of 1.0 μS/cm.
© 1994 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).