Abstract
An advanced cathodic protection coupon design which eliminates almost all of the soil IR drop during current-on potential measurements has been developed. Potential measurements are made through a slot in the geometric center of the coupon, a design sometimes referred to as a concentric coupon. This design greatly minimizes the electrolyte distance between the reference electrode and the coupon, which, in turn, minimizes the IR drop error contained in the measurements. This paper presents results from laboratory and field tests on this advanced coupon design.
© 2005 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).