Abstract
Corrosion behavior of a protective insulated coating (PIC) on 304 stainless steel (SS) surfaces was investigated in high temperature water under various water chemistry conditions by measuring the electrochemical corrosion potential (ECP) and flow-assisted corrosion (FAC) rate. The ECP results clearly demonstrate that the PIC layer restricted oxidant transport to the metal surface, and the ECP remained at <-230 mV(SHE) in 288°C containing high oxygen (O2) and no hydrogen (H2). In this paper, long term durability of PIC layer prepared by various coating methods will be discussed.
© 2008 Association for Materials Protection and Performance (AMPP). All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise) without the prior written permission of AMPP. Positions and opinions advanced in this work are those of the author(s) and not necessarily those of AMPP. Responsibility for the content of the work lies solely with the author(s).