The low-pressure gas pipes in some old residence communities of China are often electrically connected and groundings, which brings about great challenges to the design of cathodic protection (CP) systems due to large CP current consumption and attenuation effects. The field tests on the potential distribution of three types of anode ground beds were conducted, including a deep well auxiliary anode ground bed, shallow auxiliary anode ground bed far from gas pipes, and shallow auxiliary anode ground bed close to gas pipes. The results showed that the shallow auxiliary anode ground bed close to the gas pipe provided more protection with less current than the other two types of ground bed. Numerical simulations on CP potential distribution of different anode ground beds were conducted and the boundary conditions were determined by inversion calculation based on field tests. Based on the field test and numerical simulation results, the anode ground bed suitable for CP of low-pressure gas pipes electrically connected to groundings is the shallow auxiliary anode ground bed close to gas pipes and the optimized distribution scheme for shallow anode ground beds was proposed.
Skip Nav Destination
Article navigation
1 October 2024
Research Article|
August 06 2024
Cathodic Protection Potential Distribution and Anode Ground Bed Optimization Scheme for Low-Pressure City Gas Pipe
Dawei Zhuang;
Dawei Zhuang
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Chen Du;
Chen Du
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Yi Liang;
Yi Liang
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Xian Li;
Xian Li
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Zhongtao Cao;
Zhongtao Cao
**Beijing Gas Group Company Limited, Beijing 100035, China.
Search for other works by this author on:
Yanxia Du
Yanxia Du
‡
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2024, AMPP
2024
CORROSION (2024) 80 (10): 967–980.
Citation
Dawei Zhuang, Chen Du, Yi Liang, Xian Li, Zhongtao Cao, Yanxia Du; Cathodic Protection Potential Distribution and Anode Ground Bed Optimization Scheme for Low-Pressure City Gas Pipe. CORROSION 1 October 2024; 80 (10): 967–980. https://doi.org/10.5006/4600
Download citation file:
4
Views
Citing articles via
Suggested Reading
Failure of Magnesium Anodes in Alkaline Solution
CONF_MAR2011
Numerical Simulation of a Cathodically Protected Semisubmersible Platform Using the PROCAT System
CORROSION (June,1990)
Optimization of Cathodic Protection Systems Using Boundary Elements and Genetic Algorithms
CORROSION (November,2002)