An indoor corrosion simulation experiment device was built to explore the influence of dynamic alternating current (AC) interference on the corrosion behavior of pipeline steel under different cathodic protection (CP) levels. When the interference time in each interference cycle is 350 s, the dynamic AC corrosion rate was comparable to the steady AC corrosion rate. For JAC of 30 A/m2, the corrosion rate of the specimen can be controlled below 0.0254 mm/y when the CP current density is higher than 0.06 A/m2. As JAC is greater than or equal to 100 A/m2, with the increase of the CP current density, the corrosion rate of the specimens decreased first, then increased and decreased again. In this paper, the real-time AC/DC potential on the surface of the specimen is monitored, combined with the Pourbaix diagram and the evolution of corrosion product film. The dynamic AC corrosion mechanism under different CP levels was explored.
Skip Nav Destination
Article navigation
1 May 2023
Research Article|
March 04 2023
Research on Dynamic Alternating Current Corrosion Behavior of X65 Pipeline Steel Under Cathodic Protection Available to Purchase
Le Chen;
Le Chen
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Yanxia DU
;
Yanxia DU
‡
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
Yi Liang;
Yi Liang
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Nianpei Tian;
Nianpei Tian
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Zhenhong Zhu;
Zhenhong Zhu
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
Lei Zhang
Lei Zhang
*Corrosion and Protection Center, Institute of Advanced Materials and Technology, University of Science and Technology Beijing, No. 30 Xueyuan Rd, Haidian District, Beijing, China, 100083.
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2023, AMPP
2023
CORROSION (2023) 79 (5): 471–485.
Citation
Le Chen, Yanxia DU, Yi Liang, Nianpei Tian, Zhenhong Zhu, Lei Zhang; Research on Dynamic Alternating Current Corrosion Behavior of X65 Pipeline Steel Under Cathodic Protection. CORROSION 1 May 2023; 79 (5): 471–485. https://doi.org/10.5006/4240
Download citation file:
Citing articles via
Suggested Reading
Investigation of Alternating Current Corrosion of Cathodically Protected Pipelines: Development of a Detection Method, Mitigation Measures, and a Model for the Mechanism
CORROSION (September,2009)
Discussion on AC Corrosion Mechanism and Risk Assessment for Cathodically Protected Pipelines
CONF_APR2021