A strategy based on cathodic protection (CP) could be a practically feasible means to protect steel piping from corrosion under insulation. However, experimental studies investigating CP of steel through moist insulation are scarce. Herein, CP was explored to protect insulated steel specimens using sacrificial zinc anodes. The conditions to effectively impart CP through the moist insulation have been discussed. The “throwing power” or protection achieved using sacrificial zinc anodes coupled with mild steel specimens in moist insulation was also estimated using copper electroplating. It was validated that the efficacy of CP depends upon the ionic resistivity of the moist insulation and the moisture content (by volume) must be >25% for efficient ionic conductivity through the insulation. The maximum throwing power of CP through the insulation was achieved when zinc was in direct physical contact with mild steel, with zinc to mild steel area ratio being 1:10.
Skip Nav Destination
Article navigation
1 December 2019
Research Article|
September 30 2019
On the Mitigation of Corrosion Under Insulation (CUI) of Mild Steel Using Local Cathodic Protection
Q. Cao;
Q. Cao
‡
*Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia.
**Woodside Innovation Centre, Monash University, Clayton, Victoria 3800, Australia.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
M. Brameld;
M. Brameld
**Woodside Innovation Centre, Monash University, Clayton, Victoria 3800, Australia.
***Woodside Energy, 240 St Georges Terrace, Perth, Western Australia 6000, Australia.
Search for other works by this author on:
N. Birbilis;
N. Birbilis
****College of Engineering and Computer Science, CSIT Building Acton, The Australian National University, ACT 2601, Australia.
Search for other works by this author on:
S. Thomas
S. Thomas
*Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia.
**Woodside Innovation Centre, Monash University, Clayton, Victoria 3800, Australia.
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Received:
March 19 2019
Revision Received:
September 30 2019
Accepted:
September 30 2019
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2019, NACE International
2019
CORROSION (2019) 75 (12): 1541–1551.
Article history
Received:
March 19 2019
Revision Received:
September 30 2019
Accepted:
September 30 2019
Citation
Q. Cao, M. Brameld, N. Birbilis, S. Thomas; On the Mitigation of Corrosion Under Insulation (CUI) of Mild Steel Using Local Cathodic Protection. CORROSION 1 December 2019; 75 (12): 1541–1551. https://doi.org/10.5006/3197
Download citation file:
Citing articles via
Suggested Reading
Performance of a Volatile Corrosion Inhibitor for Mitigating Corrosion Under Insulation
CORROSION (May,2023)
Mineral Wool CUI Mitigation Improvements
CONF_MAR2024