Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) and UNS C11000 copper (Cu) were compared with respect to corrosion rate, film formation, and Cu release in two surface conditions pertinent to the use of antimicrobial functional materials. Electrochemical, surface characterization, and solution analysis methods were utilized to track the fate of copper during corrosion in synthetic perspiration solution in a freshly ground condition and after 30-d lab air passivation. Corrosion behavior was a function of both alloy composition and surface condition with slightly lower corrosion rates on Cu-5Zn-5Al-1Sn compared to Cu. Throughout the corrosion process, the majority of Cu was observed to undergo dissolution into the synthetic perspiration solution as copper cations for both materials, at concentrations that would suggest favorable antimicrobial functionality for both Cu-5Zn-5Al-1Sn and Cu, regardless of surface condition. In contrast, oxide films were thinner on Cu-5Zn-5Al-1Sn under all conditions. Hence, the combination of a slightly lower corrosion rate and a thinner oxide resulted in a similar Cu release rate for the two materials in synthetic perspiration.
Skip Nav Destination
Article navigation
1 January 2016
Research Article|
October 02 2015
The Fate of Copper During Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration Solution
Leanna L. Foster;
Leanna L. Foster
*Center for Electrochemical Science and Engineering, Department of Materials Science and Engineering, University of Virginia, Charlottesville, VA 22904.
Search for other works by this author on:
Michael Hutchison;
Michael Hutchison
*Center for Electrochemical Science and Engineering, Department of Materials Science and Engineering, University of Virginia, Charlottesville, VA 22904.
Search for other works by this author on:
John R. Scully
John R. Scully
‡
*Center for Electrochemical Science and Engineering, Department of Materials Science and Engineering, University of Virginia, Charlottesville, VA 22904.
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Received:
August 17 2015
Revision Received:
October 01 2015
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2016, NACE International
2016
CORROSION (2016) 72 (1): 51–65.
Article history
Received:
August 17 2015
Revision Received:
October 01 2015
Citation
Leanna L. Foster, Michael Hutchison, John R. Scully; The Fate of Copper During Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration Solution. CORROSION 1 January 2016; 72 (1): 51–65. https://doi.org/10.5006/1885
Download citation file:
Citing articles via
Suggested Reading
Corrosion of Cu-5Zn-5Al-1Sn (89% Cu, 5% Zn, 5% Al, 1% Sn) Compared to Copper in Synthetic Perspiration During Cyclic Wetting and Drying: The Fate of Copper
CORROSION (April,2016)
Novel Antimicrobial Heat-conducting “metallic” Coatings against Biofouling and Biocorrosion
CONF_MAR2022
Biohybrid Silver Nanocomposites as Antimicrobial Corrosion Protective Coating Materials
CONF_MAR2012