The role of different surface pretreatments on the sacrificial anode-based cathodic, as well as barrier, protection mechanisms afforded by magnesium-rich, nonchromium primer (MgRP) with and without topcoat (TC) has been investigated. Conversion coatings (chromate conversion coating, trivalent chromium-based pretreatment, and nonchromium pretreatment) and anodized coatings (without sealing, with chromate sealing, and trivalent chromium pretreatment sealing) were compared to clean and desmutted surfaces and those with a nonfilm-forming surface pretreatment with and without MgRP/TC. In preliminary studies, pretreatment chemistry and thickness were characterized using x-ray photoelectron spectroscopy and scanning electron microscopy/energy dispersive spectroscopy, while electrical properties were examined with electrochemical impedance spectroscopy. Full immersion tests in 5 wt% NaCl were conducted to evaluate the degradation characteristics of the coating and the subsequent evolution of the sacrificial anode-based cathodic protection, as well as barrier protection attributes. Factors studied included the total amount of encapsulated Mg retained in the primer, the Mg self-corrosion rate, the galvanic corrosion protection of Alloy 2024-T351 (UNS A92024), and the barrier properties. Preliminary findings for MgRP with conversion coating pretreatment and without a TC indicated that a finite full immersion exposure time was required to break down the more electrically insulating pretreatment layers. This process lowered the resistance between the MgRP and the Alloy 2024-T351 substrate and enabled sacrificial anode-based cathodic protection afforded by the MgRP. When an anodized coating was utilized as a pretreatment, cathodic protection was severely mediated as a result of the inherently high and persistent electrical resistance of this pretreatment. In contrast, Mg was galvanically coupled immediately and functioned from the start as a sacrificial anode for the nonfilm-forming pretreatment and abrasion-only pretreatments. Mg pigment depletion was tracked with x-ray diffraction in all the previously mentioned systems.
Skip Nav Destination
Article navigation
1 September 2015
Research Article|
May 18 2015
Effect of Pretreatments on Alloy 2024-T351 Corrosion Protection by Magnesium-Rich, Nonchromium Primer (MgRP): Laboratory Characterization in Full Immersion
B. Kannan;
‡ Corresponding author. E-mail:[email protected].
Search for other works by this author on:
‡ Corresponding author. E-mail:[email protected].
* Center for Electrochemical Science and Engineering, Department of Materials Science and Engineering, University of Virginia Charlottesville, VA 22904.
Received:
March 09 2015
Revision Received:
May 18 2015
Accepted:
May 18 2015
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2015 NACE International
2015
CORROSION (2015) 71 (9): 1093–1109.
Article history
Received:
March 09 2015
Revision Received:
May 18 2015
Accepted:
May 18 2015
Citation
B. Kannan, A.D. King, J.R. Scully; Effect of Pretreatments on Alloy 2024-T351 Corrosion Protection by Magnesium-Rich, Nonchromium Primer (MgRP): Laboratory Characterization in Full Immersion. CORROSION 1 September 2015; 71 (9): 1093–1109. https://doi.org/10.5006/1700
Download citation file:
Citing articles via
Suggested Reading
Environmental Degradation of a Mg-Rich Primer in Selected Field and Laboratory Environments: Part 1—Without a Topcoat
CORROSION (August,2013)
Environmental Degradation of a Mg-Rich Primer in Selected Field and Laboratory Environments: Part 2—Primer and Topcoat
CORROSION (August,2013)
Performance of a Magnesium-Rich Primer on Pretreated AA2024-T351 in Selected Laboratory and Field Environments: Anodization Pretreatment
CORROSION (January,2018)