In the present work, a new high-resolution solution for measuring degree of sensitization (DOS) of duplex stainless steel (DSS) 2205 (UNS S31803) by double loop-electrochemical potentiodynamic reactivation (DL-EPR) technique was obtained and the solution parameters were optimizing using the Taguchi method. Sensitized samples in three different conditions were chosen and five solution main factors including acid and two types of depassivator concentrations, scan rate, and surface roughness were considered. To reduce the number of experiments, Taguchi orthogonal array (OA) was used. The resulting optimal condition was to be 0.5 M sulfuric acid (H2SO4), 0.002 M sodium thiosulfate (Na2S2O3), 0.02 M sodium chloride (NaCl), and 120 grid in surface roughness and 30 mV/min scan rate. By introducing the new solution, a DOS value of 78% was obtained in the DSS2205 sample sensitized at 850°C for 40 min. Moreover, topography variations of non-sensitized and sensitized samples measured by atomic force microscopy elucidated the mechanism of austenite/ferrite boundary attack and carbide precipitates formation in sensitized samples extended to the ferrite phase.
Skip Nav Destination
Article navigation
1 March 2013
Research Article|
October 17 2012
New High-Resolution Solution for Measuring Degree of Sensitization of Duplex Stainless Steel 2205 Using Double-Loop Electrochemical Potentiodynamic Reactivation Technique Available to Purchase
M. Momeni;
‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
*Metallurgical and Materials Engineering Department, Ferdowsi University of Mashhad, Mashhad 91775-1111, Iran.
**Materials Engineering Department, Hakim Sabzevari University, Sabzevar 391, Iran.
Received:
March 29 2012
Revision Received:
July 26 2012
Online ISSN: 1938-159X
Print ISSN: 0010-9312
© 2013 NACE International
2013
CORROSION (2013) 69 (3): 230–242.
Article history
Received:
March 29 2012
Revision Received:
July 26 2012
Citation
B. Hashemi, A. Davoodi, M. Momeni, M.H. Moayed; New High-Resolution Solution for Measuring Degree of Sensitization of Duplex Stainless Steel 2205 Using Double-Loop Electrochemical Potentiodynamic Reactivation Technique. CORROSION 1 March 2013; 69 (3): 230–242. https://doi.org/10.5006/0699
Download citation file:
Citing articles via
Suggested Reading
Intergranular and Pitting Corrosion in Sensitized and Unsensitized 20Cr-25Ni-Nb Austenitic Stainless Steel
CORROSION (February,2021)
Effect of Aging Treatments on the Repassivation Potential of Duplex Stainless Steel S32205
CORROSION (October,2009)