Corrosion-inhibiting substances have been applied to suppress corrosion mainly on bare steel, but when corrosion is progressing, suppression can be achieved if anodic and cathodic reactions are avoided, which is not an easy objective, particularly if the bare metal is surrounded by concrete. In the present article, several corrosion inhibitors are studied to identify their inhibition efficiency in concrete. The percentage of reduction of the corrosion rate without and with inhibitor is named “inhibition efficiency.” This definition calls for the measurement of the corrosion rate and makes its measurement a must when studying corrosion-inhibiting substances. The most extended technique used for the corrosion rate quantification is based on the calculation of the polarization resistance, Rp. For the study presented in this article, several portable corrosion rate meters based on the Rp technique have been used. These equipment are needed for the evaluation of large structures and are able to confine the current in small areas or to determine the steel area affected by the signal for a correct corrosion rate calculation. A comparison among the different corrosion rate meters used for the inhibitor’s efficiency has been done. This comparison has indicated that the corrosion rate meter with nonefficient confinement of the current is not able to detect clearly the passivation state.
Skip Nav Destination
Article navigation
1 February 2010
Research Article|
February 01 2010
Corrosion-Inhibitor Efficiency Control: Comparison by Means of Different Portable Corrosion Rate Meters Available to Purchase
I. Martínez;
I. Martínez
‡
*Instituto Eduardo Torroja de Ciencias de la Construcción, Madrid,
Spain
.‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
C. Andrade;
C. Andrade
*Instituto Eduardo Torroja de Ciencias de la Construcción, Madrid,
Spain
.
Search for other works by this author on:
N. Rebolledo;
N. Rebolledo
*Instituto Eduardo Torroja de Ciencias de la Construcción, Madrid,
Spain
.
Search for other works by this author on:
L. Luo;
L. Luo
**Magnel Laboratory for Concrete Research, Faculty of Engineering. Gent University,
Belgium
.
Search for other works by this author on:
G. De Schutter
G. De Schutter
**Magnel Laboratory for Concrete Research, Faculty of Engineering. Gent University,
Belgium
.
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Online ISSN: 1938-159X
Print ISSN: 0010-9312
NACE International
2010
CORROSION (2010) 66 (2): 026001-1–026001-12.
Citation
I. Martínez, C. Andrade, N. Rebolledo, L. Luo, G. De Schutter; Corrosion-Inhibitor Efficiency Control: Comparison by Means of Different Portable Corrosion Rate Meters. CORROSION 1 February 2010; 66 (2): 026001–1–026001–12. https://doi.org/10.5006/1.3319663
Download citation file:
Citing articles via
Suggested Reading
Corrosion Characterization of Reinforced Concrete Slabs with Different Devices
CORROSION (February,2008)
Chloride-Induced Corrosion Behavior of Stainless Steel and Carbon Steel Reinforcing Bars in Sound and Cracked Concrete
CORROSION (October,2012)
Carbonation, Neutralization, and Reinforcement Corrosion for Concrete in Long-Term Atmospheric Exposures
CORROSION (December,2022)
Reinforcement Corrosion in Concrete Exposed to the North Sea for More Than 60 Years
CORROSION (August,2009)