The increased use of deicing salts during winter is the major cause of corrosion of offshore reinforced concrete structures. Research in the early 1970s suggested that epoxy-coated reinforcing bars might be the solution to this problem. Epoxycoating reinforcement (ECR) was well received by designers until concern about the effectiveness of the coating arose when bars in several bridges built in Florida in the early 1980s began to corrode after only a few years of service. The occurrence of this problem resulted in extensive research on the durability of structures built with ECR. This paper describes a corrosion study aimed at gaining a better understanding of the service life of ECR exposed to a chloride-contaminated environment. Corrosion monitoring has been periodically conducted on a roof of a tunnel structure built in 1984 to replace the roof made with uncoated bars that failed after 17 years of service. The present study summarizes the results of visual inspection and electrochemical testing carried out during the life of the new structure. Results indicate that after 18 years in a very aggressive environment, considering the combined action of chlorides and extreme changes in temperature, the structure is still in good condition and only a few locations show rust staining and cracking, presumably caused by corrosion of the steel reinforcement. Based on the results it would appear that fusion-bonded epoxy coating subjected to a chloride-laden environment does not provide total protection to the steel reinforcing. However, epoxy coatings have significantly extended the corrosion initiation period as compared to uncoated bars for structures subjected to a chloride environment.
Skip Nav Destination
Article navigation
1 October 2004
Research Article|
October 01 2004
Eighteen-Year Performance of Epoxy-Coated Rebar in a Tunnel Structure Subjected to a Very Aggressive Chloride-Contaminated Environment Available to Purchase
P. Montes;
P. Montes
‡
*Construction Group, CIIDIR-IPN-Unidad Oaxaca, Calle Hornos No. 1003, Sta. Cruz Xoxocotlán, CP 71230, Oaxaca,
México
.‡Corresponding author. E-mail: [email protected].
Search for other works by this author on:
T.W. Bremner;
T.W. Bremner
**Department of Civil Engineering, University of New Brunswick, PO Box 4400, Fredericton, New Brunswick, E3B 5A3,
Canada
.
Search for other works by this author on:
I. Kondratova
I. Kondratova
***NRC IIT e-business, 2 Garland Court, PO Box 69000, Fredericton, New Brunswick, E3B 6C2,
Canada
.
Search for other works by this author on:
‡Corresponding author. E-mail: [email protected].
Online ISSN: 1938-159X
Print ISSN: 0010-9312
NACE International
2004
CORROSION (2004) 60 (10): 974–981.
Citation
P. Montes, T.W. Bremner, I. Kondratova; Eighteen-Year Performance of Epoxy-Coated Rebar in a Tunnel Structure Subjected to a Very Aggressive Chloride-Contaminated Environment. CORROSION 1 October 2004; 60 (10): 974–981. https://doi.org/10.5006/1.3287832
Download citation file:
Citing articles via
Suggested Reading
Testing of Chloride Exposed Reinforced Concrete and Potential Misrepresentation of Service Performance
CORROSION (October,2015)
Effects of Reinforcement and Coarse Aggregates on Chloride Ingress into Concrete and Time-to-Corrosion: Part 2—Spatial Distribution of Coarse Aggregates
CORROSION (October,2007)