Five 1,000-h combustion tests firing 5 different coals were conducted in a 0.1-MWth fluidized bed combustion (FBC) facility at Western Kentucky University (WKU) with the operating conditions simulating those of the FBC unit at the Tennessee Valley Authority’s (TVA) Shawnee Power Station. Five coals were selected with various S and Cl contents ranging from high S (4.48%) and high Cl (0.47%) to low S (0.97%) and low Cl (0.012%). Three types of uncooled steel coupons (Types 304 [UNS S30400], 309 [UNS S30900], and 347 [UNS S34700] stainless steel [SS]) were prepared and installed, based on the advice of TVA, to simulate the evaporator tubes in the superheater region (550°C to 600°C [1,020°F to 1,100°F]). Metal wastage of each coupon was determined by measuring the thickness before and after each combustion test. In order to study the relationship between metal corrosion and ash deposits, a total of 170 ash deposits were collected from the test coupon surfaces during the 5,000-h testing and analyzed. The major components in the deposits were Ca-based compounds, with S content ~ 10% to 15%, and chloride content ~ 0.5% to 5%. It was concluded that the Ca sorbent in the FBC system can capture not only the S but also the chloride effectively, and as a result decrease the gas phase chloride concentration in the FBC system down to a level of < 60 ppm. The concentration is unlikely to have contributed much to corrosion of the metal in the FBC system. Alkali metals (K and Na) were observed only on the surface of the alloys. High S contents were found in the outer part of the deposits and appeared to be associated with Ca and Mg, suggesting that the fly ash may have reacted further after being deposited on the surface of the metal. There was good agreement between locations of high-S concentrations and high-Cr content in the inner layers of the corrosion scale on the samples, indicating that corrosion involved sulfidation attack. S is the major element causing corrosion of the metal.
Skip Nav Destination
Article navigation
1 March 2001
Research Article|
March 01 2001
The Effects of Ash Deposits on High-Temperature Corrosion of Alloys in a Fluidized Bed Combustion System Available to Purchase
J.T. Riley;
J.T. Riley
*Combustion Laboratory, Department of Chemistry, Western Kentucky University, Bowling Green, KY 42101.
Search for other works by this author on:
I.G. Wright;
I.G. Wright
**Corrosion Science and Technology, Metals and Ceramics Division, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6156.
Search for other works by this author on:
K.K. Ho;
K.K. Ho
***Illinois Clean Coal Institute, Ste. 2000, Coal Development Park, Carterville, IL 62918.
Search for other works by this author on:
A.K. Mehta;
A.K. Mehta
****Fuel Science and Combustion, Electric Power Research Institute, 3412 Hillview Ave., Palo Alto, CA 94304.
Search for other works by this author on:
S.R. Smith
S.R. Smith
*****Coal Quality and Combustion, Tennessee Valley Authority, Chattanooga, TN 37402.
Search for other works by this author on:
Received:
May 01 2000
Revision Received:
October 01 2000
Online ISSN: 1938-159X
Print ISSN: 0010-9312
NACE International
2001
CORROSION (2001) 57 (3): 253–264.
Article history
Received:
May 01 2000
Revision Received:
October 01 2000
Citation
K. Liu, W.-P. Pan, J.T. Riley, I.G. Wright, K.K. Ho, A.K. Mehta, S.R. Smith; The Effects of Ash Deposits on High-Temperature Corrosion of Alloys in a Fluidized Bed Combustion System. CORROSION 1 March 2001; 57 (3): 253–264. https://doi.org/10.5006/1.3290349
Download citation file:
Citing articles via
Suggested Reading
Corrosion of Bed Nozzle Alloys in a Wood-Waste Fluidized Bed Power Boiler
CORROSION (February,2007)
Corrosion of Alloys in a Simulated Wood-Waste Fluidizing Bed Power Boiler Environment