An experimental study of the corrosiveness of citric acid, oxalic acid, and EDTA mixtures to sensitized AISI 304 stainless steel (SS) was conducted. In initial tests, the corrosivity of various solutions at 125 C was assessed by measuring anodic polarization curves and estimating corrosion current densities (CDs), critical CDs for passivity, and passivation CDs. Based on the electrochemical results, solutions were ranked from highest to lowest according to their corrosiveness when applied to sensitized AISI 304 SS as follows: citric acid/oxalic acid, citric acid/oxalic acid/EDTA, and citric acid/EDTA. Scanning electron microscopy (SEM) and metallographic examinations of specimens exposed at rest potential to solutions of varying corrosiveness show that intergranular attack (IGA), IGA with pitting at grain boundaries, and general pitting occurred only in samples immersed in solutions containing oxalic acid. No surface attack was detected in specimens immersed in citric acid/EDTA mixtures. These results and the anodic polarization results show that of the three reagents commonly used to prepare decontamination solutions, oxalic acid is the most likely to cause IGA in sensitized AISI 304 SS. In subsequent tests, the effects of ferric ion addition were investigated using electrochemical techniques and SEM and metallographic examinations of specimens exposed to solutions of varying ferric ion concentrations. The addition of ferric ion to citric acid/oxalic acid/EDTA mixtures results in up to a threefold reduction in corrosion CDs and reduces IGA to insignificant levels in cases where it had previously been widespread and had penetrated to depths of 85 μm. For citric acid/oxalic acid mixtures, an addition of ferric ion results in decreases or increases in corrosion CDs and surface attack, depending on the initial concentration of oxalic acid present. Addition of ferric ion to citric acid/EDTA mixtures has no effect on corrosion CDs or surface damage. Hence, corrosion damage for sensitized AISI 304 SS exposed to citric acid/EDTA mixtures is negligible with or without added ferric ion.
Skip Nav Destination
Article navigation
October 1987
Research Article|
October 01 1987
Corrosiveness of Decontamination Solutions to Sensitized AISI 304 Stainless Steel
D. J. Disney
D. J. Disney
*System Chemistry & Materials Branch, Chalk River Nuclear Laboratories, Chalk River, Ontario K0J 1J0,
Canada
.
Search for other works by this author on:
Online ISSN: 1938-159X
Print ISSN: 0010-9312
National Association of Corrosion Engineers
1987
CORROSION (1987) 43 (10): 632–641.
Citation
R. A. Speranzini, R. L Tapping, D. J. Disney; Corrosiveness of Decontamination Solutions to Sensitized AISI 304 Stainless Steel. CORROSION 1 October 1987; 43 (10): 632–641. https://doi.org/10.5006/1.3583842
Download citation file:
Citing articles via
Suggested Reading
Corrosion Response of Nuclear Reactor Materials to Mixtures of Decontamination Reagents
CONF_MAR1988
Characterization and Dissolution of Deposited Magnetite Films on AISI 304 Stainless Steel Surfaces in EDTA and EDTA/Oxalate Solutions
CORROSION (February,1989)
Boiler Cleaning with Ammoniated Citric Acid
CONF_MAR1986
The Mechanism of Magnetite Dissolution in Chelant Solutions
CORROSION (April,1984)