Report of Sub-Committee VII on Accelerated Tests.ASTM Proc.,26, Pt. I, Committee Reports; Tentative Standards, 144-151 (1926).

In the Bureau of Standards sodium chloride spray test the specimens are placed within an enclosed space and subjected to a fog of 20% solution. The specimens are removed every 24 hours, brushed with a stiff bristle brush and examined.

Report of Committee B-3 on Corrosion of Non-Ferrous Metals and Alloys.ASTM Proc.,27, Pt. I, Committee Reports; Tentative Standards, 281-298 (1927).

With the present technique, the applicability of the spray test is limited and the method offers little promise as a general means for determining the corrosion-resistance of metals. A submitted plan prepared for a tentative standard spray test apparatus includes: 1) 24 by 20 in. glazed stoneware tank with baffle plate; 2) ¼-inch glass rods for specimen suspension; 3) ¼-inch glass tube inlet; 4) 2-inch glass tube exhaust;...