CUI (Corrosion Under Insulation) is a key degradation in facilities and pipelines and known to drive 40% - 60% failures in the piping systems. CUI is known to trigger from the soaked insulations that are held in contact with the metal(s). Although high operating temperatures are perceived to reduce CUI risks, integrity issues happen due to condensation or sweating once the pipe/ equipment is brought through cyclic temperatures or transient conditions. With lower or even ambient temperatures, the content of liquid moisture within the insulation increases which ends up exploiting CUI risk. This issue of soaking becomes more pronounced in mothballed equipment/ pipes as there is no moth-balling method known that can keep the insulation dry once the pipeline is out of service. This article addresses the case study where the soaked insulations on pre-existing operational and out-of-service multi-kilometer pipelines were trialed for moisture retention affinity. Moisture readings were taken on candidate configuration on a biweekly basis over a period of 7 months. Both i.e., operational, and mothballed lines were also trialed with a novel moisture removal system namely Insulation Ventilation System employing low point drains, ventilation windows, and perforated stand-offs between the insulation and external jacketing. The operational segments of the pipeline with moisture removal systems in place exhibited the least moisture trapping and reduced TOW (time of wetness).